EC FILTER
24/85/250 KW
DRY ELECTRIC FILTER
The EC filter with protected technology is available in various sizes. It is the perfect supplement that makes your biomass heating system even more environmentally responsible. It operates in a two-stage mode: coarse flue gas particles are separated out by the integral cyclone. The electric filter, encased in the immersion pipe of the cyclone, filters the fine dust from the flue gas. The height of the immersion pipe of the cyclone can be adjusted. Consequently, the flue gas can flow through the bypass in certain operating phases. This is particularly necessary during the start-up and non-stationary phases.
Highest level
of convenience
It's all a matter of technology
BENEFITS AT A GLANCE
- The EC filter is suitable for floorstanding and wall mounted installations (except EC filter 250)
- Very low wearing and low maintenance
- Extremely low energy consumption
- Two-stage separation (pre-separation via cyclone; fine dust separation inside the electric filter)
- Highly compact design
- Extremely high level of separation
- Automatic filter cleaning
- Integral bypass circuit
- May be retrofitted (requires a touchscreen controller on the boiler)
Specification
Tabelle zum scrollen
Name | EC filter 24 P | EC filter 24 | EC filter 85 | EC filter 250 | Unit |
---|---|---|---|---|---|
Output range | 7 - 33 | 7 - 24 | 20 - 85 | up to 250 | kW |
Filter dimensions (W x H x D) | 430 x 1045 x 440 | 430 x 1600 x 440 | 430 x 1600 x 440 | 720 x 2100 x 820 | mm |
Weight | ca. 65 | approx. 90 | approx. 90 | approx. 180 | kg |
Flue outlet | Ø 130 | Ø 130 | Ø 180 | Ø 250 | mm |
Power supply | 230 | 230 | 230 | 230 | V |
Power drawn | max. 30 | max. 30 | max. 30 | max. 60 | Watt |
Max. electrode voltage | 30 | 30 | 30 | 30 | kV |
Min. clearance towards the ceiling | 300 (optimal 750) | 300 (optimal 750) | 300 (optimal 750) | 400 (optimal 850) | mm |
Ash box capacity | 12 | 32 | 32 | 65 | Litre |
Cleaning | automatic | automatic | automatic | automatic | |
Ash discharge interval | 1 to 3 times per heating season | 1 to 3 times per heating season | 1 to 3 times per heating season | 1 to 3 times per heating season | |
Suitable for boilers | Therm / Biostar / Hybrid | BIOSTAR 12-33 / BIOSMART / BIO-VARIO / BIO-HYBRID | POWERCHIP-BIOCOM- POWERCORN bis 85kW / BMK / BMK VARIO-P / BMK-HYBRID | for boilers from 85 kW | |
Cascade | pro Grundgerät ein EC Filter | one EC filter per standard appliance | one EC filter per standard appliance | one EC filter per standard appliance |